Quick Details
Warranty: | 3months-1year | Type: | On-line |
Place of Origin: | Guangdong, China | Application: | INSTRUMENTATION |
Brand Name: | SOROTEC | Name: | Ups Power Supply |
Model Number: | IPS9335 | Rated voltage: | 380/400/415 Vac three-phase |
Phase: | Single Phase | Voltage range: | ±20% |
Protection: | Overcurrent | Frequency range: | 50/60Hz±5% |
Weight: | other | Power factor: | 0.9 |
DC Voltage: | 384VDC | AC ripple voltage: | <1% |
Supply Ability
Packaging & Delivery
Quantity(Pieces) | 1 - 1000 | >1000 |
Est. Time(days) | 30 | To be negotiated |
Key Features:
1.Adopt full digital control technology.
2.Intelligent detection and monitoring function.
3.Digital control and static switch zero switching.
4.Input/output full isolation
5.DC UPS isolated with utility power completely.
6.Cubicle design with power standard.
7.Multifunctional protection for overvoltage,low voltage,
8.Overcurrent, short circuit and so on.
9.Large-screen LCD monitor Chinese and English operation interface.
10.Ultralong 256 event records, user-friendly analysis and management to the situation of power supply.
11.Static bypass has a strong anti-overload capacity.
Control System:
Adopt microprocessor bus control technology and ensure the real-time control of rectifier, inverter, static switch as well as coordination of each power part, characterized by increased control of aging, higher reliability, enhance the efficiency of complete UPS system and the output technical parameters are better than that of the general capacity of equipment.
Rectifier :
6 pulse or 12 pulse fully controlled bridge (6 or 12 SCR) composed of rectifier, its function is input AC 380V rectified for DC 435V or so. Control features for the "slope" start, that is to say the output voltage of rectifier within 10 seconds from the 0V to 435V and no impact on the power grid.
Model Power(kVA) |
IPS9335C 10-160KVA | |||||||||
10KVA | 15KVA | 20KVA | 30KVA | 40KVA | 60KVA | 80KVA | 100KVA | 120KVA | 160KVA | |
Capacity | 9KW | 13.5KW | 18KW | 27KW | 36KW | 54KW | 72KW | 90KW | 108KW | 144KW |
Input | ||||||||||
Rated voltage | 380/400/415 Vac three-phase | |||||||||
Voltage range | ±20% | |||||||||
Frequency range | 50/60Hz±5% | |||||||||
Power factor | ≥0.9 | |||||||||
Current harmonic distortion |
<5% wuth harmonic filter | |||||||||
Soft Start | 0-100% in 10′′ | |||||||||
Bypass Input | ||||||||||
Rated voltage | 380/400/415 Vac three-phase | |||||||||
Permitted voltage range | ±15%(selsetable from ±10% to±25% from front panel) | |||||||||
Rated frequency | 50/60Hz | |||||||||
Permitted frequency range | ±2%(selectable from ±1% to ±5% from front panel) | |||||||||
Standard features | BackFeed portection;split bypass line | |||||||||
Batter | ||||||||||
Type | Maintenance-free lead-acid VRLA AGM/GEL; | |||||||||
DC Voltage | 384VDC | |||||||||
AC ripple voltage | <1% | |||||||||
Inverter output | ||||||||||
Rated voltage(V) | 380/400/415Vac | |||||||||
Regulation of the output voltage |
348-424Vac phase/neutral(from contril panel) | |||||||||
Crest factor(lpeak/irms) | 3:1 | |||||||||
static stability | ±1% | |||||||||
Dynamic stability | ±5% | |||||||||
Frequency | 50/60Hz configurable | |||||||||
Overload | 110% 125% 150% of the rated current for 1h/10′/1′ | |||||||||
Frequency stability | ±0.05% on mains failure | |||||||||
Remote signaling | Voltage-free contacts | |||||||||
Remote controls | EPO and Bypass | |||||||||
Communication | RS232 + romote contacts | |||||||||
Operation temoerature | 0°C-40°C | |||||||||
Relative humidity | <95% non condensing | |||||||||
Colour | RAL7035 | |||||||||
Noise | 54dB at 1m | 50-65dB at 1m | ||||||||
Protection degree | IP42 | |||||||||
Effciency Smart Mode | UP to 98% | |||||||||
Compliance | Safety:EN 62040-1-1(Directive 2006/95/EC);EMC:6200-2(Directive 2004/108/EC) | |||||||||
Weight(KG)N.W | 200 | 220 | 230 | 290 | 340 | 440 | 520 | 770 | 855 | 1300 |
Dimensions:(WxDxH)mm | 560*730*1220 | 800*855*1600 | 900*855*1900 | 1250*855*1900 | ||||||
Internal batteries | Yes | Yes | Yes | Yes | No | No | No | No | No | No |