SOROTEC IndustrialUPS IPS9335 Multifunctional protection for overvoltage,low voltage

Short Description:

Output Voltage:10KVA/15KVA/20KVA/30KVA/40KVA/60KVA/80KVA/100KVA/120KVA/160KVA
Lead Time:
Quantity(Pieces) 1 – 1000 >1000
Est. Time(days) 30 Negotiable


Product Detail

Overview

Quick Details

Warranty: 3months-1year Type: On-line
Place of Origin: Guangdong, China Application: INSTRUMENTATION
Brand Name: SOROTEC Name: Ups Power Supply
Model Number: IPS9335 Rated voltage: 380/400/415 Vac three-phase
Phase: Single Phase Voltage range: ±20%
Protection: Overcurrent Frequency range: 50/60Hz±5%
Weight: other Power factor: 0.9
DC Voltage: 384VDC AC ripple voltage: <1%

Supply Ability

Supply Ability:5000 Piece/Pieces per Month Ups Power Supply

Packaging & Delivery

Packaging Details:Carton, export type packing or according to your requirement.
Port:Shenzhen
Lead Time :

Quantity(Pieces) 1 - 1000 >1000
Est. Time(days) 30 To be negotiated

Product Description

Key Features:
    1.Adopt full digital control technology.
    2.Intelligent detection and monitoring function.
    3.Digital control and static switch zero switching.
    4.Input/output full isolation
    5.DC UPS isolated with utility power completely.
    6.Cubicle design with power standard.
    7.Multifunctional protection for overvoltage,low voltage,
    8.Overcurrent, short circuit and so on.
    9.Large-screen LCD monitor Chinese and English operation interface.
    10.Ultralong 256 event records, user-friendly analysis and management to the situation of power supply.
    11.Static bypass has a strong anti-overload capacity.

     Control System:
    Adopt microprocessor bus control technology and ensure the real-time control of rectifier, inverter, static switch as well as coordination of each power part, characterized by increased control of aging, higher reliability, enhance the efficiency of complete UPS system and the output technical parameters are better than that of the general capacity of equipment.

      Rectifier :
    6 pulse or 12 pulse fully controlled bridge (6 or 12 SCR) composed of rectifier, its function is input AC 380V rectified for DC 435V or so. Control features for the "slope" start, that is to say the output voltage of rectifier within 10 seconds from the 0V to 435V and no impact on the power grid.

Specification

Model
       Power(kVA)
IPS9335C 10-160KVA
10KVA 15KVA 20KVA 30KVA 40KVA 60KVA 80KVA 100KVA 120KVA 160KVA
Capacity 9KW 13.5KW 18KW 27KW 36KW 54KW 72KW 90KW 108KW 144KW
Input
Rated voltage 380/400/415 Vac three-phase
Voltage range ±20%
Frequency range 50/60Hz±5%
Power factor ≥0.9
Current harmonic
       distortion
<5% wuth harmonic filter
Soft Start 0-100% in 10′′
Bypass Input
Rated voltage 380/400/415 Vac three-phase
Permitted voltage range ±15%(selsetable from ±10% to±25% from front panel)
Rated frequency 50/60Hz
Permitted frequency range ±2%(selectable from ±1% to ±5% from front panel)
Standard features BackFeed portection;split bypass line
Batter
Type Maintenance-free lead-acid VRLA AGM/GEL;
DC Voltage 384VDC
AC ripple voltage <1%
Inverter output
Rated voltage(V) 380/400/415Vac 
Regulation of the
  output voltage
348-424Vac phase/neutral(from contril panel)
Crest factor(lpeak/irms)  3:1
static stability ±1%
Dynamic stability ±5%
Frequency  50/60Hz configurable
Overload 110% 125% 150% of the rated current for 1h/10′/1′
Frequency stability ±0.05% on mains failure
Remote signaling Voltage-free contacts
Remote controls EPO and Bypass
Communication RS232 + romote contacts
Operation temoerature 0°C-40°C
Relative humidity <95% non condensing
Colour RAL7035
Noise 54dB at 1m 50-65dB at 1m
Protection degree  IP42  
Effciency Smart Mode UP to 98%  
Compliance Safety:EN 62040-1-1(Directive 2006/95/EC);EMC:6200-2(Directive 2004/108/EC)  
Weight(KG)N.W 200 220 230 290 340 440 520 770 855 1300
Dimensions:(WxDxH)mm 560*730*1220 800*855*1600 900*855*1900 1250*855*1900
Internal batteries Yes Yes Yes Yes No No No No No No

Packing & Delivery

FAQ


  • Previous:
  • Next:

  • Write your message here and send it to us