Quick Details
Place of Origin: |
Guangdong, China
|
Solar Power (W): |
1000W
|
Brand Name: |
OEM
|
Type: |
transformer inverter
|
Model Number: |
SSP3115
|
charge way: |
city elcetricity, solar
|
Application: |
Home
|
color: |
optional
|
Work Time (h): |
24 Hours
|
DC voltage: |
12vdc/24Vdc/48Vdc
|
Specification: |
Normal
|
Load Power (W): |
800w 1600w 2400w 3200w 4000w
|
Output Voltage (V): |
230V
|
Supply Ability
Packaging & Delivery
1.buit-in MPPT solar charge controller
2.pure sine wave output
3. low frequency design , with transfomer
4.DIP switch for function setting
5.there's extra output socket for optional
6. well accept generator output and auto generator start port
7. full automatic and silient operation
8. automatically transfer between battery and line model
9.miroprocessor guarantee high reliability
10 remote control and BTS function
11 four steps intelligent charging control to recharge
12.bypass with AVR function (optional)
13.charge current big to 8sAmp, charge current can be adjustable from front pannel
14.mains/solar output priority for customer choose
15.main/solar/mains&solar charging priority for customer to choose
16.battery type can be choose from front pannel
Full Protection:
protection for low battery voltage,over load, output short circuit,over-temperature,restain surge interference,eliminate noise,thunder strikinget.
Application:
supply the reliable long back up time power for the home appliances and office appliance,
solar power system etc
Transformer Integrated Pure Sine Wave Solar Inverter 1000w,2000w,3000w,4000w,5000w,6000w
Capacity: 1-10Kw
Norminal Votage: 220/230/240vac
Norminal Frequency: 50/60Hz
Output Power Factor: 1
MODEL | SPS3115C 1-10KW | ||||||||
1kW | 1.5kW | 2kW | 3kW | 4kW | 5kW | 6kW | 8kW | 10kW | |
Input wave form | Sine wave (utility or generator) | ||||||||
Normal voltage | 120VAC(option) 230VAC | ||||||||
Low voltage re trip | 90V±4% & 184V/154V±4% | ||||||||
Low voltage re engage | 100V±4% & 194V/164V±4% | ||||||||
High voltage re trip | 140V±4% & 253V±4% | ||||||||
High voltage re engage | 135V±4% & 243V±4% | ||||||||
Normal input frequency | 50Hz/ 60Hz (auto detection) | ||||||||
Frequency range | 47Hz~65Hz | ||||||||
Output Wave form | (Bypass mode)same as input | ||||||||
Over-Load Protection | Circuit breaker | ||||||||
Short circuit Protection | Circuit breaker | ||||||||
Efficiency on line transfer mode | undefined95% | ||||||||
Line transfer time | 10ms Typical | ||||||||
Bypass without battery connected | Yes | ||||||||
Inverter output | |||||||||
Output wave form | Pure sine wave | ||||||||
Output continuos power watts | 1000 | 1500 | 2000 | 3000 | 4000 | 5000 | 6000 | 8000 | 10000 |
Surge ratings | 3000 | 4500 | 6000 | 9000 | 12000 | 15000 | 18000 | 24000 | 30000 |
Power factor | 0.9-1.0 | ||||||||
Nominal Output Voltage rms | 120VAC(option) 230VAC | ||||||||
Output Voltage regulation | +/- 10%rms | ||||||||
Output frequency | 50Hz ± 0.3Hz or 60Hz ± 0.3Hz | ||||||||
Short circuit protection | Yes,fault after 1 secs | ||||||||
Inverter input | |||||||||
Nominal input voltage | 24V/48V | 48V | |||||||
Minimum start voltage | 20V/40V | 40V | |||||||
Low battery alarm | 21V/42V | 42V | |||||||
Low battery trip | 20V/40V | 40V | |||||||
High voltage alarm | 32V/64V | 64V | |||||||
Charger | |||||||||
Output voltage | Dependent on battery type | ||||||||
Charge current | 10-85A MAX | 70A | 85A | ||||||
Battery initial voltage for start up | 0-15.7v for 12v(*2 for 24v;*4 for 48v) | ||||||||
Over charge protection | 15.7v for 12v(*2 for 24v;*4 for 48v) | ||||||||
Solar Charger | |||||||||
MPPT Range@Operating Voltage | 30-115VDC/60-115VDC | ||||||||
Maximum PV Array Open Circuit Voltage | 145VDC | ||||||||
Maximum Charging Current | 60A | ||||||||
Maximum Effciency | >96% |