Key Features:
1.Use advanced 6th generation DSP and full digital control technologies to realize higher system stability.
2.Output power factor is 0.9, carrying capacity than conventional UPS with 10% above, as users reduce investment cost.
3.Advanced distributed active parallel technology can realize parallel operation of 6PCS UPS units without the need of centralized bypass cabinet.
4.6-inch extra large LCD that can display 12 language (Chinese ,English,Russian,Spanish,French and so on).
5.Extra wide input voltage and frequency range make it adapt to severe power grid environment.
6.Intelligent battery management maintains battery automatically to prolong the battery life.
7.Standard input/output filter improves the system EMC performance.
8.Extra strong capability to withstand output overload and short circuit, ensuring the system stability and system safety under extreme conditions.
9.Layered independently-sealed ventilation channel and re-dundant fan, circuit boards with protective paints and a dust filter embedded make it highly efficient to dissipate heat and protect the product effectively under severe environment.
Model | GP9315C 10-120KVA | |||||||||||||
Rectifier Type | 6p | 12p | 6p | 12p | 6p | 12p | 6p | 12p | 6p | 12p | 12P | 12P | 12P | |
Rated Nominal | 10KVA/ 9KW |
20KVA/ 18KW |
30KVA/ 27KW |
40KVA/ 36KW |
60KVA/ 54KW |
80KVA/ 72KW |
100KVA/ 90KW |
120KVA/ 108KW |
||||||
Rated input voltage | 380/400/415VAC 3-phase 4-wire | |||||||||||||
Rated frequency | 50/60HZ | |||||||||||||
Input parameters | ||||||||||||||
Input voltage range | ±25% | |||||||||||||
Input frequency range | 45Hz~65Hz | |||||||||||||
Input soft start function | 0-100% 5-300settable | |||||||||||||
Input power factor | >0.8 | |||||||||||||
Input harmonic current (THDi) | <20% | |||||||||||||
Bypass | ||||||||||||||
Bypass voltage range | -20%~+15% | |||||||||||||
Bypass frequency range | 50/60HZ±10% | |||||||||||||
Output parameters | ||||||||||||||
Inverter output voltage | 220/230/240VAC 1-phase 3-wire | |||||||||||||
Voltage stability | ±1%(Steady status),±3%(Transient status) | |||||||||||||
Frequency | 50/60Hz | |||||||||||||
Mains power synchronization window | ±5% | |||||||||||||
Actually measured frequency accuracy (internal clock) | 50/60Hz±0.05Hz | |||||||||||||
Output power factor | 0.9(Output 90kW per 100kVA) | |||||||||||||
Transient response time | <5ms | |||||||||||||
Inverter overload capability | At 0.9 power factor, 110% for 1 hour, 125% for 10 minutes and 150% for 60s | |||||||||||||
Short circuit current from inverter | 3ph 1.5ln for 5seconds,1ph 2.9ln for 5seconds | |||||||||||||
DC Voltage | 360/384/432/480VDC | |||||||||||||
Maximum Bypass capability | 1000% for 100ms | |||||||||||||
Phase Shift characteristic | With 100% balanced load | <1° | ||||||||||||
With 100% imbalanced load | <1° | |||||||||||||
Total harmonic Distortion(THDv) | 100% linear load | <1% | ||||||||||||
100% non-linear load | <3% | |||||||||||||
System efficiency (full load) | Up to 94% (inverter efficiency is up to 98%) | |||||||||||||
Rectifier output parameters | ||||||||||||||
Charger output voltage stability | 1% | |||||||||||||
DC ripple voltage | ≤1% | |||||||||||||
Operating environment | ||||||||||||||
Operating temperature range | 0~40°C | |||||||||||||
Storage temperature | -25~70°C(Without battery) | |||||||||||||
Relative humidity | 0~95% No condensation | |||||||||||||
Maximum Operating Height | ≤Elevation 1000m, for elevation above 1000m, derate by 1% for every increase of 100m | |||||||||||||
Noise (1m) | 58-68dB | |||||||||||||
Protection level | IP20 | |||||||||||||
Standard | Safety: IEC60950-1 IEC62040-1-1 UL1778 EMC IEC62040-2 CLASS C2 EN50091-2 CLASS A Design and Test IEC62040-3 | |||||||||||||
Physical Parameters | ||||||||||||||
Weight(kg) | 980 | 1420 | 1200 | 1750 | 1350 | 2000 | 1600 | 2200 | 2100 | 2750 | 3690 | 6390 | 7390 | |
Dimension(WxDxh)mm | 900*855*1900 | 1250*855*1900 | 1640*855*1900 | 1250*855*1900 | 1640*855*1900 | 2280*855*1900 | 2835*1000*1950 | 3955*1090*1950 |